Welcome, Guest. Please Login.
Surveyor Corporation Surveyor SRV-1
Home Help Search Login

Surveyor Robotics Forum

Welcome to the user support forum for Surveyor SRV-1 robots, SRV-1 robot controllers and SVS stereo vision systems. To register for this forum, please send an email to support@surveyor.com which includes your desired forum user name, your registration email address, and a brief explanation of why you wish to join, and we will create a forum account for you.

Please note that there is a Search button in the forum toolbar for forum topics. Another effective search method for the entire surveyor.com site is to use Google, e.g. "xyz site://www.surveyor.com" where "xyz" is the search topic.



Pages: 1 ... 4 5 6 
Send Topic Print
configuring Matchport module via serial (Read 37062 times)
admin
YaBB Administrator
*****




Posts: 3675
Re: configuring Matchport module via serial
Reply #75 - 05/20/10 at 11:05am
 

  Expert (5) -  
     for CPU performance, enter FF
     for clk?, enter 81
     change MTU Size from 1400 to 1024
     skip the rest of the options
  WLAN (4) - set ssid and infrastructure/adhoc  - default is adhoc with SSID set to SRV1
  Channel 1 Serial (1) -  
     for Baudrate, enter -1
     for divisor, enter 2
     for flow control, enter 2
     further down, for FlushMode, enter 80
     for Pack Cntrl, enter C0
     for InterCh Time, enter 3
     skip the rest of the options
  Network (0) - set IP address - default for adhoc setup is 169.254.0.10
  Save and exit (9)
Back to top
 
 

SRV-1 Development Team
Surveyor Corporation
Email WWW   IP Logged
s.ozturk
YaBB Newbies
*




Posts: 7
Re: configuring Matchport module via serial
Reply #76 - 05/21/10 at 12:11pm
 
After applying the settings,here is the all setup:
 
 
*** Channel 1
Baudrate divisor 2, I/F Mode 4C, Flow 02
Port 10001
Connect Mode : C0
Send '+++' in Modem Mode enabled
Show IP addr after 'RING' enabled
Auto increment source port disabled
Remote IP Adr: --- none ---, Port 00000
Disconn Mode : 00
Flush   Mode : 80
Pack Cntrl   : C0
 
*** Channel 2
Baudrate 9600, I/F Mode 4C, Flow 00
Port 10002
Connect Mode : C0
Send '+++' in Modem Mode enabled
Show IP addr after 'RING' enabled
Auto increment source port disabled
Remote IP Adr: --- none ---, Port 00000
Disconn Mode : 00
Flush   Mode : 00
 
*** Expert
TCP Keepalive    : 45s
ARP cache timeout: 600s
CPU performance: Regular, clk 81
Monitor Mode @ bootup : enabled
HTTP Port Number : 80
SMTP Port Number : 25
MTU Size: 1024
Alternate MAC: disabled
Ethernet connection type: auto-negotiate
 
*** E-mail
Mail server: 0.0.0.0
Unit       :
Domain     :
Recipient 1:
Recipient 2:
 
- Trigger 1
Serial trigger input: disabled
  Channel: 1
  Match: 00,00
Trigger input1: X
Trigger input2: X
Trigger input3: X
Message :
Priority: L
Min. notification interval: 1 s
Re-notification interval  : 0 s
 
- Trigger 2
Serial trigger input: disabled
  Channel: 1
  Match: 00,00
Trigger input1: X
Trigger input2: X
Trigger input3: X
Message :
Priority: L
Min. notification interval: 1 s
Re-notification interval  : 0 s
 
- Trigger 3
Serial trigger input: disabled
  Channel: 1
  Match: 00,00
Trigger input1: X
Trigger input2: X
Trigger input3: X
Message :
Priority: L
Min. notification interval: 1 s
Re-notification interval  : 0 s
 
 
*** WLAN
WLAN: enabled
Topology: Ad-Hoc
Network name: SRV1
Country: US
Channel: 6
Security suite: none
TX Data rate: 54 Mbps fixed
Power management: not supported in adhoc mode
 
 
 
 
but when I use SRV1 adhoc I am able to connect only 1 minute,After a minute SRV1 dissapears.is there anything wrong with my settings?
Back to top
 
 
  IP Logged
s.ozturk
YaBB Newbies
*




Posts: 7
Re: configuring Matchport module via serial
Reply #77 - 05/21/10 at 1:32pm
 
any advice?
Back to top
 
 
  IP Logged
admin
YaBB Administrator
*****




Posts: 3675
Re: configuring Matchport module via serial
Reply #78 - 05/21/10 at 3:57pm
 
I think you need to try to connect via infrastructure network.  We have seen many compatibility problems with adhoc, and results are not consistent.  Once you are connected to infrastructure, the performance will be very consistent.
Back to top
 
 

SRV-1 Development Team
Surveyor Corporation
Email WWW   IP Logged
s.ozturk
YaBB Newbies
*




Posts: 7
Re: configuring Matchport module via serial
Reply #79 - 05/26/10 at 12:51pm
 
thanks.I finally solve the problem.now I am able to use it as camera via program.
Back to top
 
 
  IP Logged
patrice
YaBB Newbies
*




Posts: 7
Re: configuring Matchport module via serial
Reply #80 - 09/04/10 at 9:36am
 
i'm stuck since that make long time I did't play with the robot, and can't find the driver  
 
https://www.silabs.com/Support%20Documents/Software/CP210x_VCP_Win2K_XP_S2K3.zip
 
from the start of the thread, have you something new?
Back to top
 
 
  IP Logged
tjump
Junior Member
**




Posts: 65
Re: configuring Matchport module via serial
Reply #81 - 09/06/10 at 5:57am
 
I saw your original posts from 2009. Here is a link to those.
 
http://www.surveyor.com/cgi-bin/yabb2/YaBB.pl?action=usersrecentposts;username=p atrice
 
From here I'm not sure what you need. What driver?
 
T. Jump
Back to top
 
 
  IP Logged
Pages: 1 ... 4 5 6 
Send Topic Print